2A12/CFRP电偶腐蚀行为及防护

    Study on Galvanic Corrosion Behavior and Prevention of 2A12/CFRP

    • 摘要: 采用共固化模压成型工艺制备2A12铝合金与纤维增强树脂基复合材料(有无玻璃纤维防护层)的连接件。利用电化学腐蚀、盐雾腐蚀试验研究偶合体系的电偶腐蚀行为及耐蚀性能,并结合SEM和XPS对腐蚀后试样进行形貌观察、成分分析及腐蚀机理研究。结果表明:添加玻璃纤维防护层的偶合体系平均电偶电流密度为0.112 μA/cm2,比未防护体系降低了两个数量级。进行盐雾腐蚀后,添加玻璃纤维防护层不仅能够降低腐蚀程度,还能延迟腐蚀坑出现的时间。盐雾腐蚀后铝合金表面上会有Al2O3、AlOOH和Al(OH)3存在。

       

      Abstract: The joint parts of 2A12 aluminum alloy and fiber-reinforced polymer matrix composite (with or without glass fiber protection layer) were prepared by the co-curing molding process. The electrochemical corrosion and salt spray corrosion tests were used to study the electro-couple corrosion behavior and corrosion resistance of the coupled system. SEM and XPS were combined to observe the morphology, composition analysis and corrosion mechanism research of the corroded samples. The results show that the average electric coupling current density of the coupled system with a glass fiber protection layer is 0.112 μA/cm2, which is two orders of magnitude lower than that of the unprotected system. After salt spray corrosion, adding the glass fiber protective layer can reduce the degree of corrosion and delay the appearance of corrosion pits. Al2O3, AlOOH, and Al(OH)3 are present on the surface of the aluminum after salt spray corrosion.

       

    /