Abstract:
The foam aluminum sandwich panels were prepared by ultrasonic soldering process and Sn-9Zn soldering filler metal, and the influence of the panel combination on the microstructure and low-velocity impact resistance of the foam aluminum sandwich panel was researched. The results show that the interface structure of the joints is Al/Al-Zn solid solution/α-Al+Zn-rich phase+Sn-Zn eutectic, the interface has high bonding strength, and the tensile fracture occurs in the interior of foam aluminum. Under low-velocity impact, the failure modes of aluminum foam sandwich panels are mainly manifested as plastic deformation/fracture of the panel, core layer damage and overall bending deformation. Under different panel combinations, the 1060Al/aluminum foam/1060Al sandwich plate has high impact toughness and large deformation degree, while the 1060Al/aluminum foam/2A12Al sandwich plate has a slight decrease in impact toughness, but has the minimum deformation degree of the back plate. The results underlie the optimal design of foam aluminum sandwich panel.